Description: P59407-B21 – Enlogic by nVent G3 Basic 1-Phase 3.6kVA/16A PDU for HPE

BRAND NEW WITH FULL ENLOGIC WARRANTY!!!

Overview

The P59407-B21 Enlogic by nVent G3 Basic 1-Phase 3.6kVA/16A PDU for HPE is a rack power distribution unit designed to deliver dependable electrical power to enterprise IT equipment. Supporting single-phase input at 100–240V and 16A, it provides a total rated capacity of 3.6kVA for compatible data center and server-room deployments.

Equipped with 20 IEC C13 outlets and 2 combination C13/C19 outlets, this PDU supports a range of rack-mounted servers, networking devices, and other compatible equipment. Its vertical half-height design helps organizations distribute power efficiently within supported HPE rack configurations while making effective use of rack space.

Designed for straightforward power distribution, the G3 Basic PDU is suited to businesses seeking a practical rack power solution without requiring advanced network-based outlet management. Its detachable IEC C20 input connection and included 10-foot input cord support installation planning in compatible rack environments.

Key Features – Enlogic by nVent G3 Basic PDU

  • Power Capacity: 3.6kVA rated capacity.
  • Input Power: Single-phase, 100–240V, 16A.
  • Output Outlets: 20 × IEC C13 and 2 × combination C13/C19 outlets.
  • Input Connection: Detachable IEC 60320 C20 input connection.
  • Input Cord: 10-foot input cord.
  • Power & Cooling: Designed for rack power distribution; cooling is provided by the surrounding equipment and rack environment.
  • Management: Basic power distribution; do not assume remote monitoring, metering, or outlet-level switching.
  • Protection: The official specification lists no circuit breaker for this SKU.
  • Form Factor: Vertical half-height PDU for compatible HPE rack installations.

Technical Specifications

  • Product Type: Basic rack power distribution unit (PDU).
  • Manufacturer / Brand: Enlogic by nVent for HPE.
  • Model / MPN: P59407-B21.
  • Power Capacity: 3.6kVA.
  • Input Phase: Single-phase.
  • Input Voltage: 100–240V.
  • Input Current: 16A.
  • Input Connector: IEC 60320 C20, detachable.
  • Output Connectors: 20 × C13; 2 × combination C13/C19.
  • Input Cord Length: 10 feet.
  • Circuit Breaker: None listed for this model.
  • Management Features: Basic power distribution; advanced network management features are not specified for this model.
  • Rack Compatibility: Designed for supported HPE Advanced and Enterprise racks; compatibility with third-party racks should be checked against the rack's dimensions and mounting requirements.

Physical Specifications

  • Form Factor: Vertical half-height rack PDU.
  • Weight:
    • 2.20 kg
    • 4.84 lbs
  • Dimensions (W × H × D):
    • 52.0 × 817.0 × 53.0 mm
    • 2.047 × 32.165 × 2.087 inches
  • Rack Compatibility: Supported HPE Advanced and Enterprise rack configurations, subject to rack depth and mounting compatibility.
  • Rack Height: Vertical half-height design; not a conventional horizontal 1U/2U rack-mounted unit.

Ideal For

  • Enterprise server rooms: Distributing power to compatible rack-mounted IT equipment.
  • Data center racks: Supporting server and network equipment with C13 and C19-compatible power connections.
  • HPE rack deployments: Installing power distribution in compatible HPE Advanced and Enterprise rack environments.
  • IT infrastructure refreshes: Replacing or standardizing basic rack PDUs where the required voltage, current, and outlet types match.
  • Business IT environments: Providing rack power distribution without requiring advanced remote outlet management.

Warranty & Support

  • Standard Manufacturer Warranty: Five-year Enlogic warranty, according to HPE product documentation. Confirm coverage terms for the specific unit before purchase.
  • Support Contract Compatibility: Confirm eligible service options with HPE or Enlogic based on the product's serial number and purchase details.
  • Deployment Support: Verify input power, outlet requirements, rack mounting, and connected-device load before installation.

FAQs – Enlogic by nVent G3 Basic PDU (P59407-B21)

1. What is the rated power capacity of the P59407-B21?
It supports a rated capacity of 3.6kVA with single-phase 100–240V input at 16A.

2. How many power outlets does this PDU provide?
It provides 20 IEC C13 outlets and 2 combination C13/C19 outlets. Confirm that the connectors and electrical ratings match the devices being connected.

3. Does this model support remote monitoring or switched outlets?
It is a Basic PDU. Advanced network management, remote monitoring, metering, and outlet-level switching are not specified for this SKU.

4. Does it have redundant power supplies?
No. A PDU distributes power; it is not itself a redundant power supply. Redundant power arrangements require compatible equipment and separate power feeds or PDUs where appropriate.

5. Will it fit in an HPE rack?
It is designed for supported HPE Advanced and Enterprise racks. Verify rack depth, mounting position, and available vertical space before installation.

6. What should be checked before deployment?